Products
500kw 3 Phase VFD Motor Variable Frequency
  • 500kw 3 Phase VFD Motor Variable Frequency500kw 3 Phase VFD Motor Variable Frequency

500kw 3 Phase VFD Motor Variable Frequency

CSIVEI 500kw 3 Phase VFD Motor Variable Frequency – Factory Direct from China Manufacturer. We are a professional Supplier and Exporter, offering OEM and Bulk order services. Purchase inStock units with Free Sample for testing.

The CSIVEI 500kw 3 Phase VFD Motor Variable Frequency is designed for heavy industrial and infrastructure applications. Ideal for large water treatment pumps, HVAC chillers, cement plant fans, and rubber mixers, this drive provides precise speed control with high starting torque. Advanced vector control algorithms ensure stable operation under variable torque and constant torque loads. Built-in EMC filter, dual cooling fans, and optional IP54 enclosure enhance reliability in dusty or humid environments. The drive supports Modbus, Profibus, and Ethernet/IP, enabling seamless integration with SCADA systems.

Core Parameters and Specifications


Applicable Scenarios

The food and beverage sector demands hygienic design and precise synchronization across multiple processing stages. The CSIVEI 500kw 3 Phase VFD Motor Variable Frequency is an ideal fit for powering mixers, agitators, and conveyor belts within these production lines. By enabling fine speed adjustments, csivei's CSIVEI 500kw 3 Phase VFD Motor Variable Frequency allows operators to optimize mixing consistency or precisely align product flow for accurate filling and labeling. Furthermore, the energy savings generated by avoiding constant full-speed operation contribute directly to lower manufacturing overheads. As a responsive China supplier, csivei supports it with the technical backing necessary to meet the rigorous uptime requirements of fast-moving consumer goods manufacturing.


Technical Analysis

The CSIVEI 500kw 3 Phase VFD Motor Variable Frequency integrates a comprehensive suite of hardware and software-based protection mechanisms. Input phase loss detection monitors the three-phase supply integrity to prevent rectifier damage. On the output side, electronic motor overload protection calculates the motor's thermal state based on measured current and time constants. Additional protective functions include overcurrent during acceleration/deceleration, DC bus overvoltage triggered by regenerative energy, and undervoltage lockout during supply dips. An on-board fault log retains diagnostic codes corresponding to the most recent trip events, which can be accessed via the keypad interface or communication bus for troubleshooting purposes.

FAQ

Q1: Does the 500kw 3 Phase VFD Motor Variable Frequency include a DC link choke or require an external line reactor?

A: The 500kw 3 Phase VFD Motor Variable Frequency may include an integrated DC link choke depending on the power rating. For applications with high source impedance or frequent voltage transients, an external AC line reactor is recommended to reduce harmonic distortion and protect the input rectifier.


Q2: How does it respond to a momentary power interruption?

A: It includes a ride-through function. During a brief supply voltage dip, the drive attempts to maintain output by utilizing energy stored in the DC bus capacitors. If the interruption exceeds the ride-through time, an undervoltage trip occurs and the drive must be reset before restarting.


Q3: What is the function of the PID control built into it?

A: The built-in PID controller allows it to regulate a process variable—such as pressure, flow, or temperature—directly, without an external controller. The drive adjusts motor speed to maintain the process variable at the desired setpoint based on feedback from a transducer connected to an analog input.


Q4: How does it handle regenerative energy during deceleration?

A: When the motor decelerates rapidly, it acts as a generator, returning energy to the DC bus. If the bus voltage exceeds a threshold, the drive may trip on overvoltage. An external braking resistor or braking unit can be connected to the 500kw 3 Phase VFD Motor Variable Frequency to dissipate this energy and enable faster deceleration without tripping.


Q5: What is the procedure for restoring factory default parameters?

A: To restore it to factory default settings, access the parameter initialization function. This is typically found in the utility or configuration parameter group. Confirm the action when prompted; the drive will reset and all user-modified parameters will be overwritten.

500kw 3 Phase VFD Motor Variable Frequency

Hot Tags: 500kw 3 Phase VFD Motor Variable Frequency
Send Inquiry
Contact Info

If you have any enquiry about quotation or cooperation, please feel free to email us at sanchia@csivei.com or use the following inquiry form.Our sales representative will contact you within 24 hours. Thank you for your interest in our products.


WhatsApp:8615705777705

Web:www.csiveivfd.com


X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.Privacy Policy
RejectAccept